Our engineering team held an online installation guidance meeting with an overseas customer, held before equipment arrival so that both sides could prepare the workshop in advance. The meeting was organized around documents already exchanged: site photos, floor plan dimensions, utility data and the equipment layout drawing. An engineer shared the screen to walk through the drawing section by section, while the customer's project manager, electrician and factory staff joined from their side. The goal was to catch layout conflicts before machines arrive, because correcting a foundation or power connection after delivery costs far more than preparing correctly beforehand.
The meeting reviewed factory layout, foundation conditions, power supply, water connection, exhaust requirement and equipment placement. The customer shared photos showing floor condition, available doorway width, overhead clearance, existing power panel location and nearby drainage. Our engineers checked installation clearance on all sides, maintenance space behind cabinets, and whether the planned route from delivery door to installation position was wide enough. They also confirmed that foundation levelness could support the frames and that no pipe or pillar blocked the proposed line position.
Both sides confirmed the planned installation sequence, responsible contact persons, expected commissioning period and spare-part preparation. The sequence was agreed as: mechanical positioning, frame alignment, section connection, electrical wiring, control connection, empty test, material trial, parameter setting and final acceptance. Roles were assigned: the customer provides local rigging, power and water; our team guides by video and remote control. The estimated commissioning period was agreed based on line length and customer preparation status, while leaving flexible days for unexpected site work.
The team also explained safety requirements for electrical work, heating-section handling and conveyor adjustment. Local electricians were reminded to follow local code and our wiring diagram together, to check grounding before energizing, and to keep heating sections isolated when not in use. Safe lifting points on the frame were marked on the drawing, and the customer was advised to prepare suitable lifting equipment rather than improvise during installation.
This remote meeting reduces on-site misunderstanding before shipment arrival. It helps the customer prepare the workshop in advance and allows our team to build a more accurate installation plan. Any open question left after the meeting was added to a follow-up list and handled before arrival, so that when machines reach the site the team can focus on assembly instead of solving layout problems that should have been settled earlier.